Microlife Microlife
  • Consumer Products
    • BP B6 Connect_half-cuff Blood Pressure
    • NC200_front Thermometers
    • BreastPump_BC200-front Baby Care
    • NEB NANObasic_half-acc Respiratory Care
    • WS 200 BT_front Weight
    • Software_downloads_allg Software
  • Professional Products
    • WatchBP Office ABI_front_cuff WatchBP Office
    • WatchBP O3 Ambulatory 2G_half_cuff WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Cuffs and supplies
    • Software_downloads_WBP Software
  • Clinical Validations
  • Technologies
  • Health Magazine
    • icon_heart_blue Cardiovascular Health
    • icon_Temperature Fever Care
    • icon_airway-treatment Respiratory Care
    • icon_even_heat_blue Flexible Heating
  • Support
    • BP A2 Basic startseite Product Support
    • Software_downloads_allg Home-Use Software
    • Software_downloads_WBP Professional Software
    • Software Developers Developers
  • Company
    • aboutus About us
    • Events News & Events
    • contact Contact
    • History History
ASIA PACIFIC
English
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
Header Validations Microlife Flow

Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences

Home > Clinical Validations > Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences, Bonso, 2009
Share

Elisa Bonso, Francesca Dorigatti and Paolo Palatini, 2009

Validation of the Microlife soft M-L Cuff

Microlife soft wide-range cuff

The objective of this study was to determine the accuracy of the Microlife BP A100 blood pressure measuring device tested according to the requirements of the International Protocol of the European Society of Hypertension. The BP A100 model is designed to provide accurate blood pressure measurements over a wide range of arm circumferences  using a single cuff with standard-size bladder. Device evaluation was performed on 33 patients with a mean ± SD age of 59± 19 years (range 30–89 years). Their systolic blood pressure (SBP) was 143± 23mmHg (range 108–180 mmHg), diastolic blood pressure (DBP) was 87± 16mmHg (range 60–108 mmHg), and arm circumference was 31± 4cm (range 22–42 cm). In nine patients, the arm circumference was at least 33 cm. Blood pressure measurements were performed in the sitting position. The BP A100 passed all three phases of the European Society of Hypertension protocol for SBP and DBP. Mean blood pressure differences between device and observer were – 2.9±4.9mmHg for SBP and – 2.6± 4.6mmHg for DBP. Similar device–observer differences were observed in the patients divided into two subgroups according to whether their arm circumference was above or below the median in the group. In conclusion, the present results indicate that the Microlife BP A100 monitor coupled with a single cuff with standard size bladder provides accurate blood pressure readings over a wide range of arm circumferences. 

Click here to download the abstract in pdf format.

Header Validations Microlife

Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences, Bonso, 2010

View clinical validation
Microlife_PAD_WristDevice_Header

Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2:2013 protocols, Bing, 2015

View clinical validation
Header Validations Microlife

Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension, Belghazi, 2007

View clinical validation
Microlife
  • Support
  • Contact
  • Developers
  • Imprint
  • Privacy policy
  • Terms of use
Login
Copyright © 2025 - Microlife Corporation. All rights reserved.