Microlife Microlife
  • Consumer Products
    • BP B6 Connect_half-cuff Blood Pressure
    • NC200_front Thermometers
    • BreastPump_BC200-front Baby Care
    • NEB NANObasic_half-acc Respiratory Care
    • WS 200 BT_front Weight
    • Software_downloads_allg Software
  • Professional Products
    • WatchBP Office ABI_front_cuff WatchBP Office
    • WatchBP O3 Ambulatory 2G_half_cuff WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Cuffs and supplies
    • Software_downloads_WBP Software
  • Clinical Validations
  • Technologies
  • Health Magazine
    • icon_heart_blue Cardiovascular Health
    • icon_Temperature Fever Care
    • icon_airway-treatment Respiratory Care
    • icon_even_heat_blue Flexible Heating
  • Support
    • BP A2 Basic startseite Product Support
    • Software_downloads_allg Home-Use Software
    • Software_downloads_WBP Professional Software
    • Software Developers Developers
  • Company
    • aboutus About us
    • Events News & Events
    • contact Contact
    • History History
ASIA PACIFIC
English
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
Header Microlife & WatchBP Clinical Studies Flow

Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation

Home > Clinical Validations > Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation, Wiesel, 2014
Share

Joseph Wiesel, MDa*, Benjamin Arbesfeld, MDb, and David Schechter, MDc, 2014

Abstract

Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age ‡50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p <0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice.

Click here to download the abstract in pdf format

Click here to view this abstract on PubMed.gov