Microlife Microlife
  • Consumer Products
    • BP B6 Connect_half-cuff Blood Pressure
    • NC200_front Thermometers
    • BreastPump_BC200-front Baby Care
    • NEB NANObasic_half-acc Respiratory Care
    • WS 200 BT_front Weight
    • Software_downloads_allg Software
  • Professional Products
    • WatchBP Office ABI_front_cuff WatchBP Office
    • WatchBP O3 Ambulatory 2G_half_cuff WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Cuffs and supplies
    • Software_downloads_WBP Software
  • Clinical Validations
  • Technologies
  • Health Magazine
    • icon_heart_blue Cardiovascular Health
    • icon_Temperature Fever Care
    • icon_airway-treatment Respiratory Care
    • icon_even_heat_blue Flexible Heating
  • Support
    • BP A2 Basic startseite Product Support
    • Software_downloads_allg Home-Use Software
    • Software_downloads_WBP Professional Software
    • Software Developers Developers
  • Company
    • aboutus About us
    • Events News & Events
    • contact Contact
    • History History
ASIA PACIFIC
English
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SLOVENIJA - Slovenščina
  • SUOMI - Suomi
  • SCHWEIZ - Français
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • TÜRKIYE - Türkçe
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
Asia
  • ASIA PACIFIC - English
  • VIỆT NAM - Tiếng Việt
  • ประเทศไทย - ไทย
  • 中国 - 中文
  • 台灣 - 中文
Middle East and North Africa
  • MENA - Arabic عربى
USA, Latin America
  • US - English
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
Menu
Header Microlife & WatchBP Clinical Studies Flow

Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor profile

Home > Clinical Validations > Automated determination of the ankle-brachial index using an oscillometric blood pressure monitor: validation vs. Doppler measurement and cardiovascular risk factor profile, Kollias, 2011
Share
Anastasios Kollias, Apostolos Xilomenos, Athanase Protogerou, Evangelos Dimakakos and George S Stergiou, 2011

Abstract

The ankle-brachial index (ABI) is a method used widely for peripheral arterial disease (PAD) diagnosis and cardiovascular risk prediction. This study validated automated ABI measurements taken using an oscillometric blood pressure (BP) monitor allowing simultaneous arm–leg BP measurements. A total of 93 patients (hypertension 83%; dyslipidemia 72%; diabetes 45%; cardiovascular disease 23%; smoking 15%) were submitted to Doppler and automated ABI measurements, performed using a professional oscillometric BP monitor (Microlife WatchBP Office; triplicate simultaneous arm–leg BP measurements), in a randomized order. The mean difference between the Doppler reading (1.08±0.17) and (1) the first oscillometric ABI reading was 0.03±0.11, (2) the average of two oscillometric readings was 0.02±0.10 and (3) the average of three oscillometric readings was 0.02±0.09 (Po0.01 for all). Strong correlations were found between oscillometric and Doppler ABI (r 0.80, 0.85 and 0.86 for single and average of two and three oscillometric readings, respectively; Po0.001 for all). Agreement between oscillometric and Doppler ABI in diagnosing PAD (Doppler ABI o0.9) was found in 95% of cases (j 0.79; agreement in diabetics: 94%, j 0.79). A receiver operating characteristic (ROC) curve revealed area under the curve at 0.98, with a 0.97 oscillometric ABI cutoff for optimal sensitivity (92%) and specificity (92%) in diagnosing PAD. Average time for automated ABI measurement was 5.8 vs. 9.3 min for Doppler (Po0.001). Doppler and oscillometric ABI were associated and predicted (multivariate regression analysis) by the same cardiovascular risk factors (pulse pressure, smoking and cardiovascular disease history). Automated ABI measurement using a professional BP monitor allowing simultaneous arm–leg BP measurements appears to be a reliable and faster alternative to Doppler measurement.

Click here to download abstract as PDF

WatchBP Office Central_front_cuff

WatchBP Office Central

View product
WatchBP Office ABI_front_cuff

WatchBP Office ABI

View product
Microlife
  • Support
  • Contact
  • Developers
  • Imprint
  • Privacy policy
  • Terms of use
Login
Copyright © 2025 - Microlife Corporation. All rights reserved.